AS-POI

Active SYM Point-of-Interface

  • POI
  • /
  • AS-POI

The Active SYM Point of Interface (ASPOI) is the preferred 3rd party DAS POI due to its innovative approach to remotely manage and monitor the DAS systems power levels via its intelligent and intuitive GUI.

Active SYM Point-of-Interface

Features

  • Flexibility & Scalability

    Its modular design allows mix-and-match of different band cards. You can add more cards as you go.

  • Dual Power Mode

    It handles up to 48dBm on High Power Mode and 38dBm on Low Power mode which allows for a lower insertion loss for low power radios of only 2~3.5dB

  • Built-in CW tone Generator

    With integrated CW tone generation, it streamlines CW test procedures without walkie-talking between two installers, significantly reducing DAS commissioning time.

  • Safe Mode

    In the event of power failure, it bypasses to “Safe Mode” to ensure continuous service. The downlink path will maintain its attenuation levels with no change, and the uplink will default to 7.5dB insertion loss.

  • Monitoring Ports

    Each card has a physical monitoring port for both uplink (8dB coupling) and downlink (31dB or 41dB coupling), eliminating the need to put external couplers.

  • One-Click As-built Report

    With a single click of the mouse, users can download the entire daisy chain as-built report for site commissioning.

  • Remote Command & Control

    One connection (One IP) gives you bird’s-eye view of all daisy-chained units (One as a Host and the other 14 as Remotes)Allows multi-user access with different access rightsWeb-based GUI and no proprietary software required.

  • Power Monitoring & Alarm Monitoring

    It produces graphic charts for each card’s downlink input power changesPower level is measured every hour. Results are stored, analyzed and charted for one year worth of data.

Models

Model Description Downlink Freq. Uplink Freq.
S600 600MHz 617-652MHz 663-698MHz
S700L 700MHz Lower A, B, C Band 728-746MHz 698-716MHz
S700 700MHz Upper C Band 746-757MHz 776-787MHz
S700P 700MHz FirstNet Band 758-768MHz 788-798MHz
S800N 800MHz Full SMR Band 851-869MHz 806-824MHz
S800S 800MHz Partial SMR Band 862-869MHz 817-824MHz
S850 850MHz Cellular Band 869-894MHz 824-849MHz
S1900 1900MHz EPCS Band 1930-1995MHz 1850-1915MHz
S2100N 2100MHz AWS 1 & 3 Band 2110-2180MHz 1710-1780MHz
S2300 2300MHz WCS Band 2350-2360MHz 2305-2315MHz
S2600N 2600MHz BRS Band 2496-2690MHz
S3700N 3700MHz C-Band 3450-3980MHz
D700L 700MHz Lower A, B, C Band 728-746MHz 698-716MHz
D700 700MHz Upper C Band 746-757MHz 776-787MHz
D700P 700MHz FirstNet Band 758-768MHz 788-798MHz
D850 850MHz Cellular Band 869-894MHz 824-849MHz
D1900 1900MHz EPCS Band 1930-1995MHz 1850-1915MHz
D2100 2100MHz AWS 1 & 3 Band 2110-2180MHz 1710-1780MHz
SPC2W 2×2-way Combiner/Splitter 698-2700MHz
SPC4W 1×4-way Combiner/Splitter 698-2700MHz

Point-of-Interface

Innovative Visual Block Diagram GUI

User Interface design is so intuitive that we don’t believe one would need to read the user manual to set up and maintain the active SPOI. – When you daisy chain the units, remote units are automatically recognized and registered in the Host unit.

Point of Interface

ASPOI for udit Replacement

Category UDIT(Westell) ASPOI(SYM)
Model Part# Part# Description Datasheet
POI Module U-P1DL70050DDQA CS18-115-161Q S700L 700 MHz Lower A, B, C Band Card FDD Standard Cards
U-P1DU70050DDQA CS18-115-162Q S700 700 MHz Upper C Band Card
U-P1D800050DDQA CS18-115-168Q S700P 700 MHz FirstNet Band Card
U-P1D850050DDQA CS18-115-164Q S850 850 MHz Cellular Band Card
U-P1DP10050DDQA CS18-115-165Q S1900 1900 MHz PCS Band Card
U-P1DA30050DDQA CS18-115-166Q S2100N 2100 MHz AWS 1 & 3 Band Card
U-P1DA30050DDQA CS18-115-166Q S2300 2300 MHz WCS Band Card
N/A N/A S600 600MHz B71 Band Card
N/A N/A S2600N 2600 MHz TDD BRS Band Card S2600N BRS TDD Card
N/A N/A S3700N 5G TDD 3450-3980MHz, A.110/CBRS/C-Band Card S3700N Broadband 5G TDD Card
Chassis Subrack
& Controller
UDIT-CH1-CM1D-XXEN-194U-12BP CS18-115-128 SP-MFC Controller,
-48VDC power and main frame chassis,
4U Subrack with 8 blank panels
SP-MFC Main Controller
Subrack Chassis
UDIT-CH1-CM1D-XXEN-194U CS18-115-127
UDIT-CM1D-XXEN CS18-115-101
UDIT-CH1-194U CS18-115-100
UDIT-1UCM CS18-115-124
Splitter
Module
U-SC14PX CS18-115-113 SPC4W 2x 4‐way Combiner/Splitter Card SPC2W & SPC4W
N/A N/A SPC2W 4x 2‐way Combiner/Splitter Card
AC Power UDIT-PS-48VMOD CS18-200-100 RU1-1048 19" 1U Rackmount,
AC to -48VDC Power Converter
19" 1U AC/DC Power Converter
RU1-1048
UDIT-PSCH-148VMOD CS18-200-101
UDIT-PSCH-248VMOD CS18-200-102

Additional Information